| Host Bus Interface Specifications: |
| Speed |
|
64-bit, 133-MHz PCI-X |
| Single voltage |
|
3.3 V and 5.0 V buses supported |
| Compliance |
|
PCI Local Bus Specification rev. 2.2, PCI-X Addendum rev. 1.0a, PCI Hot Plug Specification 1.0, PCI Bus Power Management Interface Specification rev 1.1 |
| Fibre Channel Specifications |
| Speed 1 & 2 Gbps autosensing |
|
200 MBps per port maximum at half-duplex
400 MBps per port maximum at full-duplex |
| Topology |
|
FC-AL, FC-AL-2, point to point, switched fabric (FL_Port and F_Port) |
| Buffer credits |
|
For 512-byte frame size, 9 credits issued.
For 2K-byte frame size, 3 credits issued. |
| Class of service |
|
Class 3 Fibre Channel service |
| Protocols |
|
SCSI-FCP, IP, FC-TAPE |
| Compliance |
|
Second Generation FC Generic Services Definition (FC-GS-2), Third eneration FC Generic Services Definition (FC-GS-3), Fibre hannel-Physical and Signaling Interface (FC-PH), SCSI-3 Fibre Channel Protocol (SCSI-FCP), Fibre Channel-Arbitrated Loop-2 (FC-AL-2), Fibre Channel-Private Loop Direct Attach Technical Report (FC-PLDA), RFC 2625 IP and APR Over Fibre Channel, Fibre Channel Framing and Signaling (FC-FS) |
| Physical Specifications |
| Ports |
|
Two |
| Media |
|
Multimode optic |
| Optics |
|
Short wave laser |
| Connections |
|
Two LC-style connectors that support non-OFC, multimode fibre optic cabling using small form factor optical transceiver modules |
| Form factor |
|
Low-profile MD2: 16.93 cm×5.15 cm (6.7"×2.5") |
| Bracket size |
|
QLA2342: standard size
|
| Environment and Equipment Specifications |
| Airflow |
|
0 lf/m |
| Temperature |
|
Operating: 0°C/32°F to 55°C/131°F
Storage: ?20°C/?4°F to 70°C/158°F |
| Humidity |
|
Relative (non-condensing): 10% to 90%
Storage: 5% to 95% |
| Power dissipation |
|
~ 7.0 watts |
| Cable |
|
50/125µm multimode fiber
62.5/125 µm multimode fiber |
| Cable distances |
|
1 Gbps: 500 meters 50/125 µm fiber, 300 meters 62.5/125 µm fiber
2 Gbps: 300 meters 50/125 µm fiber, 150 meters 62.5/125 µm fiber |
| Agency Approvals?Product Safety |
| US/Canada |
|
UL, cUL: UL60950, CSA C22.2 No.60950, Class 1 Laser Product per DHHS 21CFR J |
| Europe |
|
73/23/ECC Low Voltage Directive:
TUV: EN60950: 1992+A1,2,3,4,11, EN60825-1: 1994+A11, EN60825-2: 1994 |
| Agency Approvals?EMI and EMC |
| US |
|
FCC Part 15, Class B |
| Canada |
|
Industry Canada ICES-003, Class B |
| Europe |
|
89/336/EEC EMC Directive CE Mark, EN55022: 1998/CISPR22:1997 Class B, EN55024: 1998, EN61000-3-2:1995, EN61000-3-3:1994 |
| Japan |
|
VCCI, Class B |
| Taiwan |
|
CNS 13438 Class B |
| New Zealand/Australia |
|
AS/NZS 3548 Class B |
| Korea |
|
MIC |
| Tools and Utilities |
| Management tools |
|
FC HBA Manager |
| Device utilities |
|
Command line interface; configuration utilities resident with BIOS and FCode |
| Boot support |
|
Intel x86: BIOS (32-bit), EFI (64-bit); Solaris SPARC: FCode |
| APIs |
|
SNIA HBA API V2, SMI-S, and FDMI |
| Operating systems* |
|
Windows Server 2003 (32-bit and 64-bit), Windows NT, Windows 2000, Solaris SPARC, Linux (32-bit and 64-bit), Novell NetWare, Mac OS X |